Effects of Ultrasonic Cleaning
Does ultrasonic cleaning have an adverse effect on crystals or other components on a PCBA?
Effects of Ultrasonic Cleaning
If there is a negative affect are there any ultrasonic cleaning methodologies that would prevent problems?
K.U.
|
The answer is no. The answer is yes.
Take your pick. There are two schools on this subject. Smart, intelligent, and experienced engineers will tell you that there is significant risk of component damage when exposed to ultrasonic energy. From damaged crystals to wire bond fractures, that fact is that there is the possibility of damage. In fact, several years ago, a major assembler of electronic assemblies published data linking component damage to ultrasonic energy. In reality, while the above statements are true, the chance of component damage on modern ultrasonic cleaning equipment is rare. Modern ultrasonic cleaning equipment utilizes frequencies of 40 kHz. The frequency is "swept" up and down to reduce potential component damage. Also, if the watts to fluid volume is low enough, damage will be further reduced. Here's the real issue. It doesn't really which school of thought you subscribe to. What matters is what your customer, QC manager, reliability engineer, and others think.
The
fact that there is legitimate belief that ultrasonic energy has the
potential to cause component damage normally precludes it from being
used to
preform a defluxing process.
The
fact that you are asking this question, illustrates my point that
ultrasonic energy is not openly accepted in the defluxing world, despite
compelling
arguments to the contrary.
I would strongly recommend spray-in-air technology for your cleaning / defluxing requirements. It is universally accepted as the conventional wisdom for defluxing applications and is never suspected of contributing to component damage. |
|
Mike Konrad
President Aqueous Technologies Mr. Konrad has been in the electronic assembly equipment industry since 1985. He is founder and CEO of Aqueous Technologies Corporation, a manufacturer of automatic de-fluxing equipment, chemicals, and cleanliness testing systems. |
|
We have several published articles available for download on our
web site, click on the
"Recommended Reading" button.
The article by B.P. Richards et al. "Does
Ultrasonic Cleaning of PCBs Cause Component Problems: An Appraisal"
best addresses your question: "Does Ultrasonic cleaning have an adverse
affect on crystals
or other components on a PCBA?" My paper, "Reducing the Cost of
Misprinted PCBs", addresses the parameters that would help prevent
potential problems.
I also recommend the IPC-7526, "Stencil and Misprinted Board Cleaning Handbook."
|
|
Bill Schreiber
President Smart Sonic Corporation Mr. Schreiber developed the original ultrasonic stencil cleaning process in 1989. Obtained the only EPA Verification for specific parameters of Environmental Safety, User Safety and Cleaning Efficiency for a stencil cleaning process. |
|
If the frequency of the crystal matches the frequency of the ultrasound, then there is resonance and the component can fail.
Regular cleaners are better than ultrasonic cleaners precisely for this reason.
|
|
Karthik Vijay
Technical Manager - Europe Indium Corp. Currently with Indium Corporation and responsible for technology programs and technical support for customers in Europe. Over 15 yrs experience in SMT, Power, Thermal & Semiconductor Applications. Masters Degree in Industrial Engg, State University of New York-Binghamton. |
|
In
the early days of integrated circuits, say the 1960s and 1970s,
ultrasonic cleaning was generally not used for cleaning components. The
affect was
not on the crystals or components themselves, but on the leads going
through the packaging.
Repeated,
high-powered ultrasonic cleaning simply vibrated the leads too
strongly, causing metal fatigue and component failure. This was
particularly
true for military and aerospace systems, which actually banned
ultrasonic cleaning in one of the now-long-forgotten mil specs.
Modern
ultrasonic cleaners use "sweep" frequency management to avoid this
problem. The machines change frequency constantly, so the energy is
never
on a harmonic frequency of the lead for very long, and never at the
same power setting, which has been proven to minimize damage to
components.
At
the same time, I think every expert would urge careful and thorough
testing on your boards, your components and your systems before
certifying the
process to be trouble-free.
A
better answer might be to look at vapor degreasing. Vapor degreasing is
a much gentler form of cleaning that does not need ultrasonics to work
well.
Check out one source at Micro Care, Why is Cleaning With Vertre Better than Cleaning With Water
or Some Other Solvent ? or another option is
Does MicroCare Have Any Solvents Suitable for Use in Vapor Degreasers?
|
|
Mike Jones
Vice President Micro Care Mr. Jones is an electronics cleaning and stencil printing specialist. Averaging over one hundred days a year on the road, Mike visits SMT production sites and circuit board repair facilities in every corner of the globe, helping engineers and technicians work through the complex trade-offs today's demanding electronics require. |